المنتجات الموصى بها
متجر
عرض 961–975 من أصل 1941 نتيجة
-
قواطع تيار
GV4APN01 Extended Rotary Handle Black, IP54
- TeSys GV extended rotary handle, for motor circuit breakers GV4 mounted inside an enclosure and to be operated externally.
- For main switch usage, it provides a black handle on grey front plate with indication of 3 positions OFF, ON, TRIP.
- To be mounted on the door of the enclosure, the handle mechanism ensures an IP54 protection to the mounting.
SKU: n/a -
قواطع تيار
GV4APN02 Extended Rotary Handle Red, IP54
- TeSys GV extended rotary handle, for motor circuit breakers GV4 mounted inside an enclosure and to be operated externally.
- For emergency switch usage, it provides a red handle on yellow front plate with indication of 3 positions OFF, ON, TRIP.
- To be mounted on the door of the enclosure, the handle mechanism ensures an IP54 protection to the mounting.
SKU: n/a -
قواطع تيار
GV4APN04 Extended Rotary Handle Red, IP65
- TeSys GV extended rotary handle, for motor circuit breakers GV4 mounted inside an enclosure and to be operated externally.
- For emergency switch usage, it provides a red handle on yellow front plate with indication of 3 positions OFF, ON, TRIP.
- To be mounted on the door of the enclosure, the handle mechanism ensures an IP65 protection to the mounting.
SKU: n/a -
قواطع تيار
GV4AS027 Voltage release, MX coil coil, 24VAC/DC
- TeSys GV electrical trip unit, MX shunt trip, 24V AC 50Hz/60Hz or 24V DC, for motor circuit breakers GV4.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
قواطع تيار
GV4AS057 Voltage Release, 48 V AC, 50/60Hz, 48 V DC
- TeSys GV electrical trip unit, MX shunt trip, 48V AC 50Hz/60Hz or 48V DC, for motor circuit breakers GV4.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
قواطع تيار
GV4AS137 Voltage Release – 110~130 V AC, 50/60Hz,125 V DC
- TeSys GV electrical trip unit, MX shunt trip, 110-130V AC 50Hz/60Hz or 125V DC, for motor circuit breakers GV4.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
قواطع تيار
GV4AS287 Voltage Release – 220…240 V AC 50Hz – 208…277 V AC 60Hz
- TeSys GV electrical trip unit, MX shunt trip, 208-240V AC 50Hz/60Hz, for motor circuit breakers GV4.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
قواطع تيار
GV4AS487 Voltage Release – 380…415V AC 50Hz – 440…480V AC 60Hz
- TeSys GV electrical trip unit, MX shunt trip, 380-415V AC 50Hz / 440-480V AC 60Hz, for motor circuit breakers GV4.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
قواطع تيار
GV4AU027 Undervoltage Release, 24 V AC 50/60Hz, 24 V DC
- TeSys GV electrical trip unit, MN undervoltage release, 24V AC 50/60Hz and 24V DC, for motor circuit breakers GV4.
- Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc.
- Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc.
SKU: n/a -
قواطع تيار
GV4AU057 Undervoltage release, 48 V AC, 50/60Hz, 48 V DC
- TeSys GV electrical trip unit, MN undervoltage release, 48V AC 50/60Hz and 48V DC, for motor circuit breakers GV4.
- Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc.
- Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc.
SKU: n/a -
قواطع تيار
GV4AU137 Undervoltage release, 110~130 V AC 50/60Hz, 125 V DC
- TeSys GV electrical trip unit, MN undervoltage release, 110-130V AC 50/60Hz and 125V DC, for motor circuit breakers GV4.
- Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc.
- Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc.
SKU: n/a -
قواطع تيار
GV4AU286 Undervoltage release, 277 V AC 60 Hz
- TeSys GV electrical trip unit, MN undervoltage release, 277V AC 60Hz, for motor circuit breakers GV4.
- Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc.
- Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc.
SKU: n/a -
قواطع تيار
GV4AU415 undervoltage release – 380…415 V AC 50Hz
- TeSys GV electrical trip unit, MN undervoltage release, 380-415V AC 50Hz, for motor circuit breakers GV4.
- Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc.
- Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc.
SKU: n/a -
قواطع تيار
GV4L02N Motor circuit breaker, 3P, 2A, 50KA, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 2A/690V, for protection of 3-phase motors 0.25-0.75kW@400V.
- It provides magnetic protection, breaking capacity Icu 50kA@400V, start-stop control by rotary handle, connection by Everlink BTR screw terminals.
- حماية مغناطيسية قابلة للتعديل عن طريق القرص، نطاق الإعداد 6-14 بوصة.