Circuit Breaker
Showing 421–435 of 583 results
-
Circuit Breaker
GV2P20 Motor circuit breaker,3P, 13~18A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 18A/690V, for 3-phase motor applications 7.5kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 13-18A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V.
SKU: n/a -
Circuit Breaker
GV2P21 Motor circuit breaker,3P, 17~23A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 23A/690V, for 3-phase motor applications 9kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 17-23A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V.
SKU: n/a -
Circuit Breaker
GV2P22 Motor circuit breaker,3P, 20~25A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for 3-phase motor applications 11kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 20-25A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V.
SKU: n/a -
Circuit Breaker
GV2P32 Motor circuit breaker,3P, 24~32A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 24-32A, magnetic tripping at 13xIn, high breaking capacity Icu 50kA@400V.
SKU: n/a -
Circuit Breaker
GV2RT04 Motor circuit breaker, thermal magnetic circuit protector, 3P, 0.4~0.63A, Schneider
-46%Circuit BreakerGV2RT04 Motor circuit breaker, thermal magnetic circuit protector, 3P, 0.4~0.63A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for high starting current peak motor applications 0.12-0.18kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.40-0.63A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2RT05 Motor circuit breaker, thermal magnetic circuit protector, 3P, 0.63~1A, Schneider
-47%Circuit BreakerGV2RT05 Motor circuit breaker, thermal magnetic circuit protector, 3P, 0.63~1A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for high starting current peak motor applications 0.25-0.37kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.63-1A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2RT07 Motor circuit breaker, thermal magnetic circuit protector, 3P, 1.6~2.5A, Schneider
-46%Circuit BreakerGV2RT07 Motor circuit breaker, thermal magnetic circuit protector, 3P, 1.6~2.5A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for high starting current peak motor applications 0.75kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 1.6-2.5A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2RT10 Motor circuit breaker, thermal magnetic circuit protector, 3P, 4~6.3A, Schneider
-46%Circuit BreakerGV2RT10 Motor circuit breaker, thermal magnetic circuit protector, 3P, 4~6.3A, Schneider
- HTeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for high starting current peak motor applications 2.2kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 4-6.3A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2RT14 Motor circuit breaker, thermal magnetic circuit protector, 3P, 6.3~10A, Schneider
-46%Circuit BreakerGV2RT14 Motor circuit breaker, thermal magnetic circuit protector, 3P, 6.3~10A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for high starting current peak motor applications 2.2kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 4-6.3A, a magnetic tripping level at 20xIn, high breaking capacity Icu 100kA@400V.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2RT20 Motor circuit breaker, thermal magnetic circuit protector, 3P, 13~18A, Schneider
-46%Circuit BreakerGV2RT20 Motor circuit breaker, thermal magnetic circuit protector, 3P, 13~18A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 18A/690V, for high starting current peak motor applications 7.5kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 13-18A, a magnetic tripping level at 20xIn, high breaking capacity Icu 15kA@400V.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2RT21 Motor circuit breaker, thermal magnetic circuit protector, 3P, 17~23A, Schneider
-46%Circuit BreakerGV2RT21 Motor circuit breaker, thermal magnetic circuit protector, 3P, 17~23A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 23A/690V, for high starting current peak motor applications 9-11kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 17-23A, a magnetic tripping level at 17xIn, high breaking capacity Icu 15kA@400V.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV3APN02 TeSys GV3 – rotary handle kit – IP54 – red – for GV3L & GV3P
- TeSys GV extended rotary handle, for motor circuit breakers GV3L, GV3P mounted inside an enclosure and to be operated externally.
- For emergency switch usage, it provides a red handle on yellow front plate with indication of 3 positions OFF, ON, TRIP.
- To be mounted on the door of the enclosure, the handle mechanism ensures an IP54 protection to the mounting.
SKU: n/a