- 
Circuit breaker size S2 for motor protection, Class 10 A-release 36…45 A Short-circuit release 585 A Screw terminal Standard switching capacity, Phased-out product, Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2031-4VA10<<
- number of poles for main current circuit is 3
- adjustable current response value current of the currentdependent overload release
 36…45 A
- operating voltage rated value 20 … 690 V
- operating frequency rated value 50 … 60 Hz
- operational current rated value 45A
		Circuit Breaker
		
	
			3RV1031-4GA10 Circuit breaker, (36-45)A, 690V, Siemens
				Availability: 
				50 in stock
- 
Circuit breaker size S2 for motor protection, Class 10 A-release 36…45 A Short-circuit release 585 A Screw terminal Standard switching capacity, Phased-out product, Successor is SIRIUS 3RV2 Preferred successor type is >>3RV2031-4VA10<<
- number of poles for main current circuit is 3
| Weight | 1060 g | 
|---|---|
| Dimensions | 150 × 55 × 140 cm | 
Based on 0 reviews
Only logged in customers who have purchased this product may leave a review.
 
			
 GV2ME07 Motor circuit breaker,3P, 1.6~2.5A,thermal magnetic
GV2ME07 Motor circuit breaker,3P, 1.6~2.5A,thermal magnetic						 EZC400N3320 circuit breaker EasyPact CVS400F, 36 kA 320A
EZC400N3320 circuit breaker EasyPact CVS400F, 36 kA 320A						 GV2ME08 Motor circuit breaker,3P, 2.5~4A,thermal magnetic
GV2ME08 Motor circuit breaker,3P, 2.5~4A,thermal magnetic						 LC1D50AM7 contactor 3P, (3NO) AC-3, 440V, 50A, 240V AC coil, Schneider
LC1D50AM7 contactor 3P, (3NO) AC-3, 440V, 50A, 240V AC coil, Schneider						 LC1D38M7 Contactor 3P, 38A, 220V AC, Schneider
LC1D38M7 Contactor 3P, 38A, 220V AC, Schneider						 GV2ME04 Motor circuit breaker,3P,0.4~0.63A,thermal magnetic
GV2ME04 Motor circuit breaker,3P,0.4~0.63A,thermal magnetic						 LC1D18M7 Contactor 3P, 18A, 220V AC, Schneider
LC1D18M7 Contactor 3P, 18A, 220V AC, Schneider						 LC1D80M7 Contactor 3P, 80A, 220V AC, Schneider
LC1D80M7 Contactor 3P, 80A, 220V AC, Schneider						 GV2ME03, Motor circuit breaker,3P, 0.25~0.4A,thermal magnetic
GV2ME03, Motor circuit breaker,3P, 0.25~0.4A,thermal magnetic						 LC1D95M7 contactor - 3P(3 NO) - 440 V 95 A - 220 V AC coil
LC1D95M7 contactor - 3P(3 NO) - 440 V 95 A - 220 V AC coil						 LC1D65AM7 contactor - 3P(3 NO) -  440 V 65 A - 220 V AC coil
LC1D65AM7 contactor - 3P(3 NO) -  440 V 65 A - 220 V AC coil						 LC1D32M7 Contactor 3P, 32A, 220V AC, Schneider
LC1D32M7 Contactor 3P, 32A, 220V AC, Schneider						 GV2ME02 Motor circuit breaker 3P,0.16~0.25A,thermal magnetic
GV2ME02 Motor circuit breaker 3P,0.16~0.25A,thermal magnetic						 GV2ME06 Motor circuit breaker, 3P, 1~1.6A,thermal magnetic
GV2ME06 Motor circuit breaker, 3P, 1~1.6A,thermal magnetic						 LC1D40AM7 contactor, 3P(3 NO), 440 V 40 A, 220V AC coil, Schneider
LC1D40AM7 contactor, 3P(3 NO), 440 V 40 A, 220V AC coil, Schneider						 LC1D25M7 Contactor 3P, 25A, 220V AC, Schneider
LC1D25M7 Contactor 3P, 25A, 220V AC, Schneider						 S203-C32 MCB 3P 32A ABB
S203-C32 MCB 3P 32A ABB						 S201-C25  10KA 25A  ABB
S201-C25  10KA 25A  ABB						 LC1D115M7 Contactor, 3P, 3NO, 440 V, 115 A, 220 V AC coil, Schneider
LC1D115M7 Contactor, 3P, 3NO, 440 V, 115 A, 220 V AC coil, Schneider						 NF63-HW 20A Circuit breaker
NF63-HW 20A Circuit breaker						 S803B-C80   80A 16KA  ABB
S803B-C80   80A 16KA  ABB						









There are no reviews yet.