  • GV3P13 is a TeSys GV motor circuit breaker from Schneider Electric.
  • It ensures thermal-magnetic protection for motors 5.5kW@400V and high breaking capacity Icu 100kA.
  • Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V.
  • GV3P13 is a TeSys GV motor circuit breaker from Schneider Electric designed for motor applications 5.5kW@400V.
  • It fulfills a thermal-magnetic protection with a thermal setting range 9-13A, magnetic tripping at 14xIn and high breaking capacity Icu 100kA@400V.

7.360,00 EGP 13.630,00 EGP

Out of stock

Compare
  • GV3P13 is a TeSys GV motor circuit breaker from Schneider Electric. It ensures thermal-magnetic protection for motors 5.5kW@400V and high breaking capacity Icu 100kA.
  • Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V.
  • GV3P13 is a TeSys GV motor circuit breaker from Schneider Electric designed for motor applications 5.5kW@400V.
  • It fulfills a thermal-magnetic protection with a thermal setting range 9-13A, magnetic tripping at 14xIn and high breaking capacity Icu 100kA@400V.
  • Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3 415V.
  • Available worldwide, it is multi-standards certified (IEC, UL, CSA, CCC, EAC, Marine) and Green Premium compliant (RoHs/Reach).
  • Complete motor protection in a single device , short-circuit, overload, disconnection.
  • Associated with a TeSys contactor, it ensures a complete type 1 or type 2 Motor Starter solution.
  • Compact, 55mm wide, for DIN-rail and panel mounting.
  • Manual control with rotary knob for Start / Stop, padlockable.
  • Possible mounting of auxiliary contacts front or side mounted (GVAE, GVAN, GVAD) for status and tripping signaling.
  • For large industrial or building LV distribution networks thanks to a high 100kA breaking capacity.
  • Power connections with EverLink BTR screw connectors providing constant tightening pressure.
  • Can be associated with undervoltage or shunt tripping units (GVAU, GVAS) and power distribution busbars (GV3G).

 

 

SHOPPING CART

close

التغيير المستمر في الأسعار - نظراً للإرتفاعات المتتالية للأسعار وعدم إستقرار سعر الصرف والإستيراد مع عد إستطاعة بعض موردينا بإمدادنا بقوائم أسعار نهائية ومستقرة للمنتجات المعروضة بمتجرنا. لذا نرجو من سيادتكم مشكورين إرسال طلباتكم عبر تطبيق الواتس اب ليقوم فريق المبيعات بدراسة كل طلب وتقديم السعر المناسب والدعم الفني اللازم . نرجو تفهم موقفنا وإستعدادنا الدائم لخدمتكم .. املين إستقرار الأوضاع قريباً . Dismiss