Circuit Breaker
GV2LE32 Circuit Breaker 3P, 32A, Schneider
- TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V.
- It provides a magnetic protection with a tripping level at 13xIn, high breaking capacity Icu 10kA@400V.
- Connection by screw clamp terminals.
SKU: n/a -
Circuit Breaker
GV2MC01 Enclosures for GV2ME, IP41, Schneider
- TeSys enclosed starters, empty enclosure, for thermal magnetic circuit breakers GV2ME.
- Surface mounting enclosure with screw fixing, 2 knock-outs for cable glands on top and bottom, sealable cover.
- Polycarbonate enclosure, double insulated with protective conductor, IP41 protection.
SKU: n/a -
Circuit Breaker
GV2MC02 Enclosures for GV2ME, IP55, Schneider
- TeSys enclosed starters, empty enclosure, for thermal magnetic circuit breakers GV2ME.
- Surface mounting enclosure with screw fixing, 2 knock-outs for cable glands on top and bottom, sealable cover.
- Polycarbonate enclosure, double insulated with protective conductor, IP55 protection.
SKU: n/a -
Contactors & Protection Relays
GV2ME01 Motor circuit breaker 3P,0.1~0.16A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 0.16A/690V, for 3-phase motor applications less than 0.06kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.1-0.16A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME02 Motor circuit breaker 3P,0.16~0.25A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 0.25A/690V, for 3-phase motor applications 0.06kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.16-0.25A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME023 Motor circuit breaker,3P,0.16~0.25A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 0.25A/690V, for 3-phase motor applications 0.06kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.16-0.25A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME03, Motor circuit breaker,3P, 0.25~0.4A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 0.4A/690V, for 3-phase motor applications 0.09kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.25-0.4A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME033, Motor circuit breaker,3P, 0.25~0.4A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 6.3A/690V, for 3-phase motor applications 2.2kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 4-6.3A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME04 Motor circuit breaker,3P,0.4~0.63A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.4-0.63A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME043 Motor circuit breaker,3P, 0.4~0.63A,thermal magnetic
@media (max-width: 768px) {
.youtube-top-overlay, .youtube-bottom-overlay {
height: 20%; /* Adjust overlay height for mobile screens */
}
}- TeSys GV motor circuit breaker, 3 poles (3P), 0.63A/690V, for 3-phase motor applications 0.12-0.18kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.4-0.63A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME05 Motor circuit breaker, 3P, 0.63~1A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 1A/690V, for 3-phase motor applications 0.25kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.63-1A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME06 Motor circuit breaker, 3P, 1~1.6A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 1.6A/690V, for 3-phase motor applications 0.37-0.55kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 1-1.6A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME063 Motor circuit breaker, 3P, 1~1.6A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 1.6A/690V, for 3-phase motor applications 0.37-0.55kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 1-1.6A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: n/a -
Contactors & Protection Relays
GV2ME07 Motor circuit breaker,3P, 1.6~2.5A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 2.5A/690V, for 3-phase motor applications 0.75kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 1.6-2.5A, magnetic tripping at 13xIn, high breaking capacity Icu 100kA@400V.
SKU: 50
Pipe rol 16 mm Mustafa Mahmoud
C10B3TM025 MCCB, 3P, 25A, 25KA, Schneider
LRD14 thermal overload relays - 7...10 A
XB4BA21 Push button metal flush black Ø22 Schneider
LRD32 Thermal overload relay 23...32 A
XMLB010A2S11 Electric pressure switch 10 bar - adjustable scale 2 thresholds - 1 C/O
LRD10 thermal overload relays, 4...6 A, Schneider
Pipe Rol 23mm Mustafa Mahmoud
GV2ME04 Motor circuit breaker,3P,0.4~0.63A,thermal magnetic
LRD365 thermal overload relays - 48...65 A
C10B3TM050 MCCB, 3P, 50A, 25KA, Schneider
LC1D50AM7 contactor 3P, (3NO) AC-3, 440V, 50A, 240V AC coil, Schneider
GV2ME02 Motor circuit breaker 3P,0.16~0.25A,thermal magnetic
FH202 AC-40/0.03 40A 30MA ABB
LRD22 Thermal overload relay 16...24 A
GV2ME03, Motor circuit breaker,3P, 0.25~0.4A,thermal magnetic
GV4LE25N Motor circuit breaker GV4 3P 25A Icu 50 kA
C10B3TM032 MCCB, 3P, 32A, 25KA, Schneider
C10B3TM100 MCCB, 3P, 100A, 25KA, Schneider
C10B3TM063 MCCB, 3P, 63A, 25KA, Schneider
C10B3TM040 MCCB, 3P, 40A, 25KA, Schneider
GV2ME07 Motor circuit breaker,3P, 1.6~2.5A,thermal magnetic 