- TeSys D contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3/3e (5.5kW@400V).
- It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals.
SKU: n/a -
Contactors & Protection Relays
GV2ME01 Motor circuit breaker 3P,0.1~0.16A,thermal magnetic
- TeSys GV motor circuit breaker, 3 poles (3P), 0.16A/690V, for 3-phase motor applications less than 0.06kW@400V.
- It provides a thermal-magnetic protection with a thermal setting range 0.1-0.16A, magnetic tripping at 9xIn, high breaking capacity Icu 100kA@400V.
SKU: 50
-
-
Circuit Breaker
GVAS385 Shunt release, 380/400V AC 50Hz / 440V AC 60Hz
- TeSys GV electrical trip, MX shunt release, 380-400V AC 50Hz / 440V AC 60Hz, for motor circuit breakers GV2, GV3.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
Circuit Breaker
GVAS225 Shunt release, 220-240V AC, 50Hz
- TeSys GV electrical trip, MX shunt release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
-
-
-
Circuit Breaker
GVAS385 Shunt release, 380/400V AC 50Hz / 440V AC 60Hz
- TeSys GV electrical trip, MX shunt release, 380-400V AC 50Hz / 440V AC 60Hz, for motor circuit breakers GV2, GV3.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
Circuit Breaker
GVAS225 Shunt release, 220-240V AC, 50Hz
- TeSys GV electrical trip, MX shunt release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3.
- It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a -
-
Products Grid
Best Sellers
Recently Added
Circuit Breaker
GVAS385 Shunt release, 380/400V AC 50Hz / 440V AC 60Hz
TeSys GV electrical trip, MX shunt release, 380-400V AC 50Hz / 440V AC 60Hz, for motor circuit breakers GV2, GV3.
It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a
Circuit Breaker
GVAS225 Shunt release, 220-240V AC, 50Hz
TeSys GV electrical trip, MX shunt release, 220-240V AC 50Hz, for motor circuit breakers GV2, GV3.
It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal.
SKU: n/a
Circuit Breaker
GVAD1010 Auxiliary Contact, 1 NO + 1 NO, Schneider
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3.
1NO fault signaling contact + 1NO instantaneous auxiliary contact.
Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC.
SKU: n/a
Circuit Breaker
GVAD1001 Auxiliary Contact, 1 NC + 1 NO, Schneider
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3.
1NO fault signaling contact + 1NC instantaneous auxiliary contact.
Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC.
SKU: n/a
Circuit Breaker
GVAD0110 Auxiliary Contact, 1 NC + 1 NO, Schneider
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NO instantaneous auxiliary contact.
Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC.
Fault signling contact rated for operation up to 2A/240V AC and 1A/60V DC.
SKU: n/a
Circuit Breaker
GVAD0101 Auxiliary Contact – 1 NC + 1 NC, Schneider
TeSys GV auxiliary contact block, for motor circuit breakers GV2 and GV3. 1NC fault signaling contact + 1NC instantaneous auxiliary contact.
Instantaneous auxiliary contact rated for operation up to 6A/690V AC and 6A/240V DC.
Fault signaling contact rated for operation up to 2A/240V AC and 1A/60V DC.
SKU: n/a
Circuit Breaker
GV5P220H Motor Circuit Breaker 3P, 220A, 70KA, Schneider
TeSys GV motor circuit breaker, 3 poles (3P), 220A/690V, for protection of 3-phase motors 90-110kW@400V.
It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors).
SKU: n/a
Circuit Breaker
GV5P220F Motor Circuit Breaker 3P, 220A, 36KA, Schneider
TeSys GV motor circuit breaker, 3 poles (3P), 220A/690V, for protection of 3-phase motors 90-110kW@400V.
It provides thermal magnetic protection and additional protections, breaking capacity Icu 70kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors).
SKU: n/a
Circuit Breaker
GV5P150H Motor Circuit Breaker 3P, 150A, 70KA, Schneider
TeSys GV motor circuit breaker, 3 poles (3P), 150A/690V, for protection of 3-phase motors 55-75kW@400V.
It provides thermal magnetic protection and additional protections, breaking capacity Icu 36kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors).
SKU: n/a
Circuit Breaker
GV5P150F Motor Circuit Breaker 3P, 150A, 36KA, Schneider
TeSys GV motor circuit breaker, 3 poles (3P), 150A/690V, for protection of 3-phase motors 55-75kW@400V.
It provides thermal magnetic protection and additional protections, breaking capacity Icu 36kA, start-stop control by rotary handle, connection for bars or cables with lugs (direct connection of cables with additional connectors).
SKU: n/a
Circuit Breaker
GV4PEM115S Circuit Breaker 3P, 115A, 100KA, Schneider
TeSys GV motor circuit breaker, 3 poles (3P), 115A/690V, for protection of 3-phase motors 37-55kW@400V.
Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals.
Thermal protection adjustable by dials with a setting current Ir in range 65-115A and a selectable tripping class 10 or 20, magnetic protection at 17 In.
SKU: n/a
Circuit Breaker
GV4PE80S Circuit Breaker 3P, 80A, 100KA, Schneider
TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V.
It provides thermal magnetic protection and additional motor protection functions, breaking capacity Icu 100kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals.